Корзина
Профиком
+380 (68) 854-55-57
Корзина

BP 12 В / 18 А·ч Необслуживаемый герметичный свинцовый аккумулятор

BP 12 В / 18 А·ч Необслуживаемый герметичный свинцовый аккумулятор, фото 1
  • Под заказ
  • Код: BP-12V/18Ah ALG
clockОтправка с 21 августа 2026

от 6 828 ₴

+380 (68) 854-55-57
Павел
возврат товара в течение 14 дней по договоренности
BP 12 В / 18 А·ч Необслуживаемый герметичный свинцовый аккумуляторBP 12 В / 18 А·ч Необслуживаемый герметичный свинцовый аккумулятор
от 6 828 ₴
Под заказ
+380 (68) 854-55-57
Павел
Описание
Характеристики
Информация для заказа
Accumulator 12V/18AhBP 12V / 18Ah; Maintenance-free lead sealed battery; 12V / 18Ah
DI
DI/AI
DO
AI
AO
COM
SENSOR
System parameters of the central unit
Row of central unitK
User program memory192 + 64 kB
Memory for user variables / including RETAIN variables64 kB/32 kB
Instruction length2 ÷ 10 bytes
Backup of program source code in PLCYes, in program backup memory (EEPROM)
On-line program change in PLCYes, including I / O configuration change
Memory for project archiving - internal2 MB
DataBox - additional internal data memory512 kB
Optional memory card slotSD - Card Slot
Cycle time per 1k of logic instructions0,2 ms
Development environmentMosaic
Programming languagesST, IL, LD, FBD, SFC, CFC
RTC - Real time circuitNo
RAM and RTC backup 1) without / with backup batterytype. 500 hr / typ. 20,000 hours
Integrated Web serverYes
Integrated DataloggerYes
Access to PLC variables via web APIYes
Notice1) Applies to the basic module without power supply, the backup circuits are disconnected when the power supply is switched on 2) The serial interface CH1 is permanently equipped with an RS-485 interface. The serial interface type CH2 to CH4 is selectable via interchangeable submodules
COM - Communication - IP/Ethernet
Ethernet 10/100 Mb (ETHx)1
Available system modes on ETH and WLANUNI, PC, PLC, PLD
TCP / IP protocolYes
UDP protocolNo
HTTP protocolNo
WebSocket protocolNo
Protocol MODBUS/TCPNo
SMTP protocolNo
IEC 60870-5-104 protocolNo
REST APINo
COM - Serial channels
max. number of optional serial channels in the basic module4
max. number of expanding serial channels on the TCL2 bus6
Number of internal RS-232 serial channels1
Available system modes on CH5-10UNI, CSJ (CAN)
Modbus RTU / ASCII master protocolNo
Modbus protocol RTU/ASCII slaveNo
Profibus DP master protocol (<180 kbit/s)No
COM - System buses
TCL2 - system I/O bus1x TCL2 master
TCL2 - Range of one branch of the system I/O bus10 I / O modules + 4 operator panels + 6 serial channels
The communication rate of the system I / O bus345 kbps
System I / O bus terminating resistor120 Ω
CIB - Common Installation Bus (R): Installation I/O bus2x CIB master (2x 1 A)
CIB - Address range of one branch of the installation bus32 CFox I/O modules
DI - Organization of binary inputs
Total number of binary inputs4
Number of groups of binary inputs1
DI - Parameters of binary inputs DC (group A)
Number of inputs in group4
NoticeInputs DI0 - DI3 can alternatively be used as analogue inputs (AI0 - AI3). The choice is made for individual inputs from the Mosaic development environment. Due to the possible increase in interference when using analog inputs, it is not desirable to connect the common wire of the binary input switches to the AGND terminal - use GND terminal C.
DI - Parameters of binary AC inputs
Total number of binary AC inputs2
Organization of binary inputs into groups2x (IN230V, HDO)
Input voltage for log. 1230 V AC typ., 200 V AC min., 250 V AC max.
Input current at log. 1 (typ.)5 mA typ.
Delay from log. 0 to log. 110 ms
Delay from log. 1 to log. 010 ms
RO - Parameters of binary relay outputs (group A)
Parameters valid for the terminalsDO0, DO1
Number of relay outputs2
Number of output groups2
Number of outputs in group1
Organization of relay outputs into groups1x (DO0) +1 (DO2)
Output typeelectromechanical relay, unprotected output
Contact typeNO - Normally Open
DiagnoseAlarm signaling on panel module
Switching current3 A max., 100 mA min.
Switching voltage250 V AC max., 5 V AC min., 30V DC max.
Contact closing timetyp. 10 ms
Contact opening timetyp. 4 ms
Limit values of switched resistive loadmax. 3A at 30 V DC or 230 V AC
Switching inductive load limits DC13max. 1 A at 30 V DC
Switching inductive load limits AC15max. 3 A at 230 V AC
Switching frequency with rated loadmax. 20 switching / min.
Mechanical lifemin. 5,000,000 cycles
Electrical life at maximum resistive loadmin. 100,000 cycles
Electrical life at maximum load inductive DC13min. 100,000 cycles
Electrical life at maximum load inductive AC15min. 100,000 cycles
Short-circuit protectionNo
Treatment of inductive loadExternal RC element, varistor (AC), diode (DC)
Insulation voltage between outputs and internal circuits3750 V AC
Isolation voltage between groups of outputs to each other3750 V AC
AI - Organization of analog inputs
Total number of analog inputs4
Number of inputs per group4
Number of analog input groups1
Organization of analog inputs into groups4x (AI0/DI0-AI3/DI3)
Common wireMinus
Galvanic separation from internal circuitsNo
Diagnosticssignaling overload, disconnection and short-circuiting of the sensor in the status word
Type of protectionintegrated overvoltage protections
External power supplyNo
Digital resolution12 bit
Converter typeApproximation
Filtrationlow pass filter, digital comb filter 50/60 Hz
AI - Analog Input Ranges (Group A)
Passive sensorNTC Thermistor 12k / 25 °C (-40 to + 125 °C)
DI: Voltage-free contact0 when> 1.5 kOhm, 1 when <0.5 kOhm
Resistance measurement error - maximum error at 25 ° C± 0.5% of full scale
Resistance measurement error - temperature coefficient± 0.05% of full scale / K
Resistance measurement error - non-linearity± 0.09% of full scale
Resistance measurement error - repeatability at steady conditions0.07% of full scale
Max. permissible permanent overload of analog input (without damage)–20 to +30 V (each AI terminal against AGND)
Detection of disconnected sensoryes, in status word, range overflow
Power supply
Nominal supply voltage (V)24 V DC
Supply voltage, tolerances24 V DC, +25%, -15%, SELV
Supply voltage when backing up with an external battery27 V DC, +10%, –15%, SELV
Typical power input10 W
Maximum power input75 W
Module thermal/power loss6 W
Maximum current consumption (mA)3,125 A
Galvanic separation of power supply from internal circuitsNo
Internal protectionYes, PTC reversible fuse
Description of power supplyDifference between typical and maximum power input is given by possible load of CIB buses and number of switched outputs and CPU load
CIB branch power supply - parameters of the built-in master2x 1 A/ 24-27 V DC
Battery parameters24 V (2x 12V), max. 18 Ah
Continuous chargingYes, through charging circuitry in the base module
Internal protection оf backup batteryYes
Starting from backup batteryNo
Size and weight
Weight approx.300 g
Product dimensions (width x height x depth)158 x 90 x 62 mm
Module width in multiples of M (17.5 mm)9M
Module width158 mm
Module height90 mm
Module depth63 mm
Operating conditions, product standards
Product standardČSN EN 61131-2:2008 (idt IEC 61131-2:2007) - Programmable control units
Protection class of electrical objectII, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989)IP20
Operating areasNormal, according to ČSN 33 2000-3: 1995 (mod IEC 364-3: 1993)
Degree of pollution1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installationII, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of deviceModule on DIN rail
Working positionVertical
Type of operation (operating frequency)Continuous
Ambient operating temperatures-20 °C to + 55 °C
Operating temperature minimum (° C)-20°C
Operating relative humidityfrom 10 % up to 95 % without condensation
Operating atmospheric pressuremin. 70 kPa (<3,000 m above sea level)
Storage temperatures–25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / EmissionA, according to EN 55022: 1999 (mod CISPR22: 1997)
Emmisions - noteIn premises where the use of radio and television receivers can be expected to be used a distance of 10 m from these devices may cause radio interference. In such a case, the user may be required to take appropriate action.
Electromagnetic compatibility / Immunitymin. as required by EN 61131-2: 2007
Sinusoidal vibration endurance10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Packaginng, transportation, storage
DescriptionThe module is packed in a paper box according to the internal packing instructions. The package also includes this documentation. The outer packaging is carried out according to the scope of the order and the method of transport of the transport packaging provided with transport labels and other data necessary for transport. Transport of the product by the customer's own means must be carried out by covered means of transport, in a semi-european label on the packaging. The box must be stored in such a way as to prevent spontaneous movement and damage to the outer packaging. The product must not be exposed to direct weathering during transport and storage. Transportation is permitted at temperatures of -25 ° C to 70 ° C, relative humidity of 10% to 95% (non-condensing) and minimum atmospheric pressure of more than 70 kPa. The product may only be stored in clean rooms free of conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C.
Installation
Assembly descriptionThe basic module is mounted vertically on the U-rail ČSN EN 50022. The installation of the assembly (basic module and peripheral modules, if applicable) is performed according to TXV 004 10.
Attention!The device may contain parts with dangerous voltages, covers being removed, or cabling manipulated, or disconnect the appropriate circuits or turn off the power !.
Exchangeable submodulesThe optional MR-01xx submodules with serial channel 2 interface are mounted on the center plate in the CP-10x0 basic module to the position indicated in Fig. 7.1. To add or replace a submodule with a serial channel interface, release the latches on
Module operation
Module configurationThe module is operated, set up and diagnosed from the Mosaic development environment.
CommissioningThe module is ready for operation after connecting the supply voltage. The MODE button is available on the module panel to display the currently set Ethernet IP address. The parameters of all interfaces are set in the Mosaic development environment.
Module diagnosticsThe basic diagnostic system of the module is a part of its standard software. It operates from module power on and operates independently of the user. Diagnostic error states of the module and connected peripheral modules of the assembly are signaled
Maintenance
DescriptionThe module does not require any maintenance under general installation conditions.
Warranty
GenerallyWarranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. Notice: Before turning on the system, all the conditions of this documentation must be met, otherwise the protection provided by the equipment may be impaired. The system shall not be escorted unless it is verified and confirmed that the machinery incorporating the Foxtrot system meets the requirements of Directive 89/392 / CEE where applicable. All repairs and servicing of the product are performed exclusively by the manufacturer or by an authorized person. The system installer is responsible for the safety of the system.
Основные атрибуты
ПроизводительTeco
Страна производительЧехия
СостояниеНовое
  • Цена: от 6 828 ₴