Module with 4 universal AI/DI inputs and one current input 0 - 20 mA / 4 - 20mA.
DI4x DI/AI
DI/AI4x DI/AI
DO
AI1x AI current
AO
COM1x CIB slave
SENSOR
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus1x CIB slave
DI - Parameters of binary inputs DC (group A)
Number of inputs in group2
Common wireCOM
Combined input typeDI/AI Active, for sensing potential-free contacts and measuring resistance sensors
Galvanic isolation of inputs from internal/peripheral circuitsNo
Diagnosticssignaling of excited input in Mosaic
Input voltage3.3 V from internal source
Input current at log. 1 (typ.)3,3 mA
Delay from log. 0 to log. 110 ms
Delay from log. 1 to log. 0500 ms
The minimum width of the captured pulse10 ms
AI - Analog Input Ranges (Group A)
Passive sensorNTC Thermistor 12k / 25 °C (-40 to + 125 °C)
Input impedance in signal range RTD> 1 kΩ
Resistance measurement error - maximum error at 25 ° C± 2% of full scale
Resistance measurement error - temperature coefficient± 0,1% of full scale
Resistance measurement error - non-linearity± 0.2% of full scale
Resistance measurement error - repeatability at steady conditions0.5% of full scale
Detection of disconnected sensorNo
Parameter des Temperatursensors
Temperature - Measurement range-10 ÷ +50 °C
Temperature - Measurement error<5% of range
Temperature - Settling time30 min.
Valve drive parameters
Drive stroke - typical value1,5 mm
Drive stroke - maximum value2,5 mm
Valve drive speed0,05 mm/s
Adaptation of actuator with valveautomatic + manual
Flange type - thread1/2"
Automatic valve rotation30 days
Notice1) Typical stroke for most types of valves is approx. 1.5 mm. The exact stroke value can be set when configuring the module in the Mosaic environment. 2) Adaptation is performed automatically after switching on the supply voltage. Adaptation can be further started using manual control or from the user program.
Power supply
Supply voltage, tolerances24/27 V DC from CIB bus
Power supply from CIB - typical current consumption (mA)5 mA
Power supply from CIB - maximum current consumption (mA)80 mA
Power supply from CIB - internal protectionNo
Size and weight
Weight approx.125 g
Product dimensions (width x height x depth)69 x 48 x 73 mm
Operating conditions, product standards
Product standardČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999)
Protection class of electrical objectI, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989)IP10B
Operating areasNormal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installationII, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Working positionAny
Type of operation (operating frequency)Continuous
Ambient operating temperatures–10 ° C to +70 ° C
Operating relative humidityfrom 10 % up to 95 % without condensation
Operating atmospheric pressuremin. 70 kPa (<3,000 m above sea level)
Storage temperatures–25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / EmissionB, according to EN 55022: 1999 (mod CISPR22: 1997)
Packaginng, transportation, storage
DescriptionМодуль упакован в антистатический пакет. Эта документация также является частью пакета. Внешняя упаковка осуществляется в соответствии с объемом заказа и способом транспортировки в транспортной упаковке, снабженной этикетками и другими данными, необходимыми для транспортировки. Продукт не должен подвергаться воздействию прямых погодных условий во время транспортировки и хранения. Соложение продукта разрешено только в чистых помещениях. без токопроводящей пыли, агрессивных газов и паров. Наиболее подходящая температура хранения - 20 ° C.
Installation
Assembly descriptionThe C-HC-0201F-E module is mounted on the valve in any position by means of a flange. However, it is not recommended to mount the head to the valve from below, as water leaking from a leaking valve can damage the head. Installation of the assembly (basic module and possibly peripheral modules) is performed according to TXV 004 13. The figure shows an example of the C-HC-0201F-E module assembly. The C-HC-0201F-E module is mounted on the valve using a flange. A washer and insert are also inserted between the valve and the module.
Connection
Connection of power and system communicationterminal block with spring terminal 1.5 mm2, push-in
Connection of inputs / outputsterminal block with spring terminal 1.5 mm2, push-in
Module connectionThe combined module is implemented as a CIB bus module, which provides communication and power supply to the module. An example of module connection is shown in the following figure. The terminals for connecting the CIB bus are accessible after removing the head cover. In the mechanics of the module there are places for wire outlets (see Figure). According to the requirements of the application, it is possible to create openings for the passage of conductors in these places.
Function
Automatic adaptationThe C-HC-0201F module can be connected to various types of valves. The valves have different dimensions and therefore different end positions. When the supply voltage of the module (CIB bus) is switched on, it automatically adapts to the connected valve. Ie. automatic finding of the position when the valve is completely closed (0%). From this reference position, the stroke of the valve actuator can then be controlled according to the set value (eg for a typical stroke of 1.5 mm ~ 100%).
Valve configurationThe module is equipped with an autoadaptation function that adapts the thermostatic head to the valve. For the correct function of the valve, it is necessary to configure 2 parameters, which can be set when configuring the module in the Mosaic development environment. The first parameter is the offset of the valve stroke, or the extent to which we will control the valve. The typical stroke size is 1.5 mm. You can adjust the stroke size by changing the parameter. The second parameter is the relief of the valve seal. During autoadaptation, the end position "valve closed" is found, from which we control the valve in the range 0-100%. However, this end position does not take into account the denting of the seal. It would happen that the valve would not react to small values of the set opening when opening.
Manual controlFor service interventions, the module is equipped with a "MAN" button. After pressing it and releasing it in an interval of 1.5 s after the required number of flashes of the green LED, one of the actions described in the following table can be called up. Number of flashes / Actions 2 flashes: Maximum valve opening (designed to make it easier to remove the module from the valve). The valve remains open until the adaptation is called or the supply voltage is restarted. 3 flashes: Adaptation of the valve module.
Frost protectionThe internal temperature sensor is used for the frost protection function. If the measured temperature falls below 5 ° C, the actuator is set to the "fully open" position.
Module operation
CommissioningThe module is operated, set and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is indicated on the label on the module.
Module diagnosticsThe basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment. The module contains an indication LED for checking the status of inputs / outputs. By pressing the Manual Control button, the module can be switched to manual mode and the individual outputs can be controlled.
Maintenance
DescriptionThe module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
NoticeBecause the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
GenerallyWarranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
NoticeYou must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.
Основные атрибуты
ПроизводительTeco
Страна производительЧехия
СостояниеНовое
Пользовательские характеристики
DI4x DI/AI
DI/AI4x DI/AI
AI1x AI current
COM1x CIB slave
  • Цена: Цену уточняйте