Кошик
Профіком
+380 (68) 854-55-57
Кошик

CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2

CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 1
  • CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 2
  • CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 3
  • CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 4
  • CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 5
  • CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 6
  • CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 7
  • CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 8
  • CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2, фото 9
  • Під замовлення
  • Код: TXN 120 90.11NSNN
clockВідправка з 04 липня 2026

від 36 942 ₴

+380 (68) 854-55-57
Павло
повернення товару протягом 14 днів за домовленістю
CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2CP-2090, CPU/1core, 2xETH100/10, ---, 128kB databox, LCD-7mm, CH1-4, 1xCIB, 1xTCL2
від 36 942 ₴
Під замовлення
+380 (68) 854-55-57
Павло
Опис
Характеристики
Інформація для замовлення
The CP-2090 is the smallest, second-generation Foxtrot base module. It only occupies the width of 3 modules on the DIN rail. It reaches this size due to the absence of any inputs / outputs. The masters of both system expansion buses - TCL2 and CIB Common Installation Bus® - are a matter of course. It can therefore be extended in the same way as other basic modules. CP-2090 is therefore suitable as a flexible freely programmable communication center, programmable converter of interfaces and protocols, data logger with its own web server, with fast and high-capacity data storage up to 1 TB with file system, etc. Except for the built-in LTE modem, which requires a minimum width of 6M modules, the basic module CP-2090 has all the attributes of the new generation of the central unit: Communication capabilities of the basic module CP-2090:       2x Ethernet interface 100 Mbit / s, each with up to 32 simultaneous connections (programming and general IP communication)     USB micro (programming)     USB A for Flas memory, WiFi adapter (client and AP - Access point) etc.     Variant with built-in LTE modem for direct wireless connection to the Internet via a mobile network operator     Slots for up to 4 optional serial interfaces RS-485, RS-232 Power supply 24 V DC or via passive PoE - (power over Ethernet) CP-2090 is equipped with a new powerful central unit (CPU series L) with memory     1 MB for user program,     128 MB internal disk for storing files with parallel access from the LAN as a network disk,     16MB fast RAM disk     microSD card slot up to 1 TB     File management is provided by a journaling file system     Local communication with the user via OLED display (4 lines / graphic) and 6-key keyboard
DI
DI/AI
DO
AI
AO
COM2x ETH 10/100
4x Serial channel (2x free slot)
1x USB device
1x USB host
1x TCL2 master
1x CIB master
SENSOR
System parameters of the central unit
Row of central unitI
User program memory1 MB
Memory for user variables / including RETAIN variables320 kB/48 kB
Instruction length4 Byte
Backup of program source code in PLCYes, optional in Mosaic
On-line program change in PLCYes, including I / O configuration change
DataBox - additional internal data memory128/257 kB, optional
Memory for I / O data64 KB / 64 KB
File system - Internal Drive in PLC128 MB, journaling file system
File system - RAM disk PLC16 MB
File System - USB Flash DriveSupported
File system - Micro SD cardsupported (except for variants with WLAN1)
Optional memory card slotmicroSD - Card Slot (<= 1TB)
Cycle time per 1k of logic instructions0,036 ms
Cycle time for 1k integer operations0,044 ms
Cycle time for 1k floating point operations0,043 ms
Development environmentMosaic v2018.2 or higher
Programming languagesST, IL, LD, FBD, SFC, CFC
RTC - Real time circuitYes
RTC - Backup timetyp. 500 hours
Integrated Web serverYes
Integrated DataloggerYes
Access to PLC variables via web APIYes
COM - Communication - IP/Ethernet
Ethernet 10/100 Mb (ETHx)2
WLAN2 (external via USB host, optional)1
LTE interface (LTEx, optional)1
Available system modes on ETH and WLANUNI data exchange via UDP, TCP and SSL / TLS encryption support; PC EPSNET UDP / EPSNET TCP; PLC data sharing between PLCs (including CP-1xxx and CP-7xxx); PLD data sharing between PLC CP-2xxx and CP-8xxx including encryption
Available system modes on LTEUNI data exchange via UDP, TCP and SSL / TLS encryption support; EPSNET UDP / EPSNET TCP
TCP / IP protocolYes
UDP protocolYes
HTTPS protocolYes
HTTP protocolYes
WebSocket protocolYes
Protocol MODBUS/TCPYes
SMTP protocolYes
IEC 60870-5-104 protocolYes
REST APIYes
COM - USB
USB devices interface1x micro-USB
USB host interface1x USB-A
Available system modes on USBPC
COM - Serial channels
max. number of serial channels that can be serviced at one time10
max. number of internal serial channels1
max. number of optional serial channels in the basic module4
number of slots for optional submodules with interface (MR-013x)2
max. number of expanding serial channels on the TCL2 bus6 times on each TCL2 line
COM - Internal serial channels
Number of internal serial channels1x RS-485
Available system modes on the internal serial channelUNI general channel with any asynchronous communication PC communication with superior systems via EPSNET protocol MAS communication with EPSNET subordinate systems
Available communication speeds of system modes1200 Bd, 2400 Bd, 4800 Bd, 9600 Bd, 14 400 Bd, 19 200 Bd, 28 800 Bd, 38 400 Bd, 57 600 Bd, 76 800 Bd, 115 200 Bd, 172 800 Bd, 230 400 Bd, 345 600 Bd
Galvanic separation of the internal serial channelNo
Receiver sensitivitymin. ±200 mV
Signal output leveltyp. 3 V
Max. length of connected line1200 m
Note on cable lengthThe maximum length applies to twisted and shielded cable and communication speed max. 120 kBd.
COM - Submodules with serial channels and optional interface
Number of slots for submodules with optional interface (MR-013x)2
RS-232 serial channel on submodules1x on MR-0130, 2x on MR-0134
Available communication speeds of modes on the RS-232 interface1200 Bd, 2400 Bd, 4800 Bd, 9600 Bd, 14 400 Bd, 19 200 Bd, 28 800 Bd, 38 400 Bd, 57 600 Bd, 76 800 Bd, 115 200 Bd, 172 800 Bd
RS-485 serial channel on submodules1x on MR-0131, 2x on MR-0133
Available communication speeds of modes on the RS-485 interface1200 Bd, 2400 Bd, 4800 Bd, 9600 Bd, 14 400 Bd, 19 200 Bd, 28 800 Bd, 38 400 Bd, 57 600 Bd, 76 800 Bd, 115 200 Bd, 172 800 Bd, 230 400 Bd, 345 600 Bd
Available system modes on submodules MR-0130..MR-0134UNI, PC, MAS
Profibus DP serial channel on submodules1x on MR-0135
Available communication speeds of the PFB system mode9600 Bd, 19 200 Bd, 93 750 Bd, 187 500 Bd
Profibus DP master protocol (<180 kbit/s)PFB - Profibus DP Master (<180 kbit / s)
COM - Expansion communication modules on the TCL2 bus
RS-232 serial channel on modules1x on SC-1101 (either RS-232 or RS-485)
RS-485 serial channel on modules1x on SC-1101 (either RS-485 or RS-232)
Wireless M-Bus wireless communication channel on modules1x on SC-1112.T
RFox2 wireless communication channel on modules1x on SC-1111
Available communication modes on modules SC-1101, SC-1111, SC-1112UNI - universal
Modbus RTU / ASCII master / slave protocol available on mode modulesUNI - Universal
CAN serial channel on modules1x on SC-1102
Available communication modes on SC-1102 modulesCSJ - CAN bus connection
OpenTherm communication channel on modules1x on UC-12044
MP-Bus communication channel on the modules1x on UC-1203
COM - Expansion communication modules on the CIB bus - Common Installation Bus (R)
RFox2 wireless communication channel on modules1x to C-RF-0001M-A; 1x RFox2 master, max. 10 addresses
DALI Communication interface on modules1x and C-DL-0064M; 1x Master for 64 addresses
Wiegand communication interface on modules1x on C-WG-0503S; 1x Master, formats 42 bits, 34bits, 26 bits, 40bits transparent
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus1x CIB master (100 mA)
CIB - Address range of one branch of the installation bus32 CFox I/O modules
ITCL - internal system busYes
ITCL - number of exchangeable submodules2
ETCL - external system bus1 (ETH1 or ETH2)
DI - Organization of binary inputs
Total number of binary inputs11
Number of groups of binary inputs2
Organization of binary inputs into groups4x DI/AI (DI0/AI0-DI7/AI7) 6x DI/AI (HSC) (DI0/AI0-DI5/AI5) 2x DI/AI/AO (DI8/AI8/AO0-DI9/AI9/AO1) 1x DI 230 V AC (DI10)
DI - Parameters of binary inputs DC (group A)
Parameters valid for inputs on the terminalsDI0-DI9
Number of inputs in group10
Common wireminus
Input typeactive (for dry contacts connection)
Combined input typeDI/AI Active, for sensing potential-free contacts and measuring resistance sensors
Galvanic isolation of inputs from internal/peripheral circuitsNo
Diagnosticsindication of energized input by LED on module panel
Pulse input overload capacitymax. 30 V (t < 10 ms)
Input voltage for log. 0+3 V DC min.
Input voltage for log. 11 V DC max.
Input current at log. 1 (typ.)-1 mA
Delay from log. 0 to log. 1500 μs
Delay from log. 1 to log. 0500 μs
The minimum width of the captured pulse500 μs
DI - Parameters of binary AC inputs
Parameters valid for AC inputs on the terminalsDI10
Total number of binary AC inputs1
Number of groups of AC inputs1
Number of AC inputs in group1
Organization of binary inputs into groups1x DI (DI10)
DiagnosticsAlarm of excited input on the panel
Input typeconventional switch
Galvanic isolation of internal circuitsYes
Insulation voltage3750 V AC
Input voltage for log. 00 v AC min., 50 V AC max.
Input voltage for log. 1230 V AC typ. 95 V AC min., 260 V AC max.
Input current at log. 1 (typ.)5 mA typ.
Delay from log. 0 to log. 1max. 20 ms
Delay from log. 1 to log. 0max. 20 ms
HSC - Counter input parameters
The parameters are valid for inputsDI0-DI5
Special input functionsone-way counter
Counter: Input frequency / resolution1 kHz
Pulse widthmin. 500 μs
Delay from log. 0 per log. 1500 μs
Delay from log. 1 per log. 0500 μs
Range of registersup to 32 bits, 0 to 4 294 967 296
HSC - PWM input parameters
Frequency range10 Hz - 1 kHz
PWM input error<1% (at 1 kHz)
Input resolution10,4 μs (DI0), 0,2 μs (DI1)
DO/RO - Organization of binary outputs
Total number of binary outputs11
Number of binary output groups4
Organization of binary outputs into groups6x RO (DO3-DO5, DO6-DO8 3x DO (PWM) (DO0-DO2) 2x DO/AO (DO9/AO2 - DO10/AO3)
DO - Parameters of binary transistor outputs (group A)
Parameters valid for the terminalsDO0-DO2, DO9-DO10
Number of transistor outputs5
Number of output groups2
Number of outputs in group5
Organization of transistor outputs into groups3x DO (DO0-DO2) + 2x DO (DO9-DO10)
Common group conductorminus
Output typeMOSFET (Low-side switch)
Galvanic separation from internal circuitsNo
Diagnosticsindication of energized output by LED on module panel
Switching voltage5 - 30 V DC
Switching current, output load0,5 A max.
Short-term output overload capacity3 A max.
Output resistancetyp. 0,16 Ω, max. 0,4 Ω
Switching timetyp. 9 μs
Opening timetyp. 13 μs
Internal protectionovervoltage, short circuit and overheating protection
RO - Parameters of binary relay outputs (group A)
Parameters valid for the terminalsDO3-DO5
Number of relay outputs3
Number of output groups1
Number of outputs in group3
Organization of relay outputs into groups3x RO (DO3-DO5)
Output typeelectromechanical relay, unprotected output
Contact typeNO - Normally Open
Galvanic separation from internal circuitsYes
DiagnoseAlarm signaling on panel module
Switching current3 A max., 100 mA min.
Switching voltage250 V AC max., 5 V AC min., 30V DC max.
Switching power1250 VA max. for AC, 90 W max. for DC
Short-term output overload - inrush4 A max.
Current through common clamp10 A max.
Contact closing timetyp. 10 ms
Contact opening timetyp. 4 ms
Limit values of switched resistive loadmax. 3A at 30 V DC or 230 V AC
Switching inductive load limits DC13max. 3 A at 30 V DC
Switching inductive load limits AC15max. 3 A at 230 V AC
Switching frequency without loadmax. 300 switching / min.
Switching frequency with rated loadmax. 20 switching / min.
Mechanical lifemin. 5,000,000 cycles
Electrical life at maximum resistive loadmin. 100,000 cycles
Electrical life at maximum load inductive DC13min. 100,000 cycles
Electrical life at maximum load inductive AC15min. 100,000 cycles
Short-circuit protectionNo
Treatment of inductive loadExternal RC element, varistor (AC), diode (DC)
Insulation voltage between outputs and internal circuits3750 V AC
Isolation voltage between groups of outputs to each other3750 V AC
RO - Parameters of binary relay outputs (group B)
Parameters valid for the terminalsDO6-DO8
Number of relay outputs3
Number of output groups3
Number of outputs in group1
Organization of relay outputs into groups1x RO (DO6) + 1x RO (DO7) +1x RO (DO8)
Output typeelectromechanical relay, unprotected output
Contact typeNO - Normally Open
Galvanic separation from internal circuitsYes
Galvanic isolation between groupsYes
DiagnoseAlarm signaling on panel module
Switching current10 A max., 100 mA min.
Switching voltagemax. 250 V AC; max. 30 V DC; min. 5 V
Short-circuit protectionNo
Short-term output overload10A max.
Current through common clamp10 A max.
Contact closing timetyp. 10 ms
Contact opening timetyp. 4 ms
Limit values of switched resistive loadmax. 10A at 30 V DC or 230 V AC
Switching inductive load limits DC13max. 10 A at 30 V
Switching inductive load limits AC15max. 10 A at 230 V AC
Switching frequency without loadmax. 300 switching / min.
Switching frequency with rated loadmax. 6 switching / min
Mechanical lifemin. 5,000,000 cycles
Electrical life at maximum resistive loadmin. 100,000 cycles
Electrical life at maximum load inductive DC13min. 100,000 cycles
Electrical life at maximum load inductive AC15min. 100,000 cycles
Treatment of inductive loadExternal RC element, varistor (AC), diode (DC)
Insulation voltage between outputs and internal circuits3750 V AC
Isolation voltage between groups of outputs to each other3750 V AC
AI - Organization of analog inputs
Total number of analog inputs10
Number of inputs per group10
Number of analog input groups1
Organization of analog inputs into groups10 (DI0/AI0-DI9/AI9)
Input typeWith common clamp
Common wireMinus
Galvanic separation from internal circuitsNo
Diagnosticsoverload signaling in status word
External power supplyNo
Digital resolution12 bit
Converter typeApproximation
conversion time20 μs
Operating modesperiodic input sensing
Filtrationlow pass filter, digital comb filter 50/60 Hz
Insulation potential500 V DC between input and internal circuits
AI - Analog Input Ranges (Group A)
Parameters valid for inputs on the terminalsDI0/AI0 - DI9/AI9
Passive sensorKTY81-121; PTC thermistor (-55 to + 125 °C)
Input impedance in signal range RTD> 4 kΩ
Resistance measurement error - maximum error at 25 ° C± 0.5% of full scale
Resistance measurement error - temperature coefficient± 0.05% of full scale / K
Resistance measurement error - non-linearity± 0.09% of full scale
Resistance measurement error - repeatability at steady conditions0.07% of full scale
Max. permissible permanent overload of analog input (without damage)–20 to +30 V (each AI terminal against AGND)
Open input detectionNo
Detection of disconnected sensoryes, in status word, range overflow
AO - Analog output parameters
The number of groups of analogue outputs1
Number of outputs in group4
Organization of outputs in groups2x (DI8/AI8/AO0-DI9/AI9/AO1) + 2x AO (DO9/AO2-DO10/AO3)
Parameters valid for the terminalsAO0-AO3
Common wire of groupminus
Galvanic isolation from internal circuitsNo
Output typeactive voltage output
Max. permissible permanent overload (without damage)± 20 V, each terminal against AGND
Converter resolution12 bit
conversion time10 μs
Analog output error - maximum error at 25 ° C± 2% of full scale
Analog output error - temperature coefficient± 0.3% of full scale / K
Analog output error - linearity± 0.7% of full scale
Analog output error - repeatability under steady state conditions± 0.5% of full scale
External power supplyNo
Voltage output - voltage0 - 10,5 V
Voltage output - Resolution 1 LSB20,5 mV
Voltage output - maximum output current10 mA
Power supply
Supply voltage, tolerances24 V DC, +25%, -15%, SELV
Auxiliary power supply - voltageOptional: from 230 V AC mains, 40-60 Hz
Maximum power input10 W
Module thermal/power loss12 W
Internal protectionYes, PTC reversible fuse
Power supply from ETH, passive PoE - input (appliance)ETH1/Power In
Power supply from ETH, passive PoE - output (source)ETH2 / Power out, jumper configuration
Power supply from ETH, passive PoE - injector parameters24 V DC, 1A
Size and weight
Weight approx.300 g
Product dimensions (width x height x depth)158 x 90 x 58 mm
Module width in multiples of M (17.5 mm)9M
Operating conditions, product standards
Product standardČSN EN 61131-2:2008 (idt IEC 61131-2:2007) - Programmable control units
Protection class of electrical objectII, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989)IP20
Operating areasNormal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installationII, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of deviceModule on DIN rail
Working positionVertical
Type of operation (operating frequency)Continuous
Ambient operating temperatures-20 °C to + 55 °C
Operating temperature maximum (° C)+55°C
Operating temperature minimum (° C)-20°C
Operating relative humidityfrom 10 % up to 95 % without condensation
Operating atmospheric pressuremin. 70 kPa (<3,000 m above sea level)
Storage temperatures–25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / EmissionB, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015)
Emmisions - noteIn premises where the use of radio and television receivers can be expected to be used a distance of 10 m from these devices may cause radio interference. In such a case, the user may be required to take appropriate action.
Electromagnetic compatibility / Immunitymin. as required by EN 61131-2: 2007
Sinusoidal vibration endurance10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Packaginng, transportation, storage
Description
Основні
ВиробникTeco
Країна виробникЧехія
СтанНовий
Користувальницькі характеристики
COM2x ETH 10/100 4x Serial channel (2x free slot) 1x USB device 1x USB host 1x TCL2 master 1x CIB master
  • Ціна: від 36 942 ₴